DENSITY

BERTHOLD LB 480 VS. VEGA FIBERTRAC 31

Are external facility x-ray events affecting your nuclear detectors' ability to maintain a constant measurement? We put the Berthold LB480 & the VEGA Fibertrac 31 head to head to see how each would react to an external event. In our experiment, 'outside noise' is additional counts. Which detector will block the outside noise & which will allow it to affect their performance? See for yourself: 

With just the simplest of demonstrations, you will see that the Berthold transmitter provides your critical measurement with a far more stable reading during an external x-ray event. Concluded benefits from our experiment include: 

  • Optimize & Control Your Process With A Stabilized Transmitter Output
  • The Ability To Monitor Background Radiation Noise Through DTM Software
  • Creates Threshold For Soft X-Rays
  • LB480 Holds Last Known Output When Radiation Goes Above Threshold 
  • LB480 Software Begins Real-Time Measurement

Simply put, when dealing with added counts, you can't count on the competition.  We embrace the challenge to solve diverse & difficult measurements with the latest Density & Level innovations. With unmatched expertise & technology, we are your radiometric partner. 

Tired of losing your level? Schedule a walk down:

TECHSTAR NUCLEAR SERVICES

Many shy away from conducting Nuclear Services. However, TechStar Field Service is not afraid to get our hands dirty. We are trained, certified, and true technical experts on all things radiometric measurements and corresponding services. Optimize your process with your trusted nuclear service partners:

Services

Learn More

NON-CONTACT LEVEL MEASUREMENT SOLUTIONS

Our level & density measurement solutions from Berthold are non-contact and maintenance-free. They are ideally suited for use in extreme measurement environments, such as with abrasive, highly viscous, or highly corrosive media such as acids, alkalis, solutions, slurries, and suspensions.

CRYSTALSENS DETECTOR

The SENSseries LB 480 CrystalSENS is a point detector, mainly used for density, bulk flow and level switch applications. In combination with a rod source, the CrystalSENS is also used for level measurement applications where the accuracy requirements are particularly high.

Learn More

SUPERSENS DETECTOR

The SENSseries LB 480 SuperSENS Detector with its outstanding sensitivity allows for operation with extremely low source activities. Due to the high sensitivity, the SuperSENS can provide a measurement for thick-walled vessels and big tanks, where other detectors fail or need to work with unacceptably high source activities. 

Learn More

UNISENS DETECTOR

With sensitivity lengths from 0.5m up to 2.0m, the SENSseries LB 480 UniSENS rod detector is primarily used for continuous level measurements.  In order to cover even larger measuring ranges, multiple UniSENS detectors can be cascaded.

Learn More

TOWERSENS DETECTOR

The TowerSENS rod detector is designed to monitor long measuring ranges. With only one electronic transmitter and therefore only one explosion-proof housing, the TowerSENS is significantly more economical than systems comprising several short cascading detectors. 

Learn More

 

 

TECHSTAR NUCLEAR SERVICES

Coker OptionsThe extra sensitivity that the Berthold gauges have over the competition allows you to keep using the existing sources for more than 30 years. If the other guys are recommending you change your source, it's because their detector simply cannot keep up. Learn of your upgraded options in our blog:

Read The Blog | Discover Your Options